HOT OIL TEMPERATURE CONTROL UNITS
HOT OIL TEMPERATURE CONTROL UNITS
MetalPress THC-S and THC-D hot oil temperature control units circulate thermal oil through molds, dies, platens, rolls and other process equipment. Both series operate from 140–570 °F (60–300 °C).
Choose a single-zone THC-S unit with 18–72 kW of heating or a dual-zone THC-D unit with 18–48 kW per zone. Size the pump, process connections and cooling around your equipment.
GET A QUICK HOT OIL TCU QUOTE
Send us your process details and we’ll help size the correct THC unit.
HELP US SIZE THE RIGHT HOT OIL TCU
For the fastest recommendation, include:
Application & Process Equipment
Mold, die, platen, roll, press or other equipment
Required Temperature Range
Normal setpoint and maximum operating temperature
Number of Zones
Single- or dual-zone temperature control
Heat Load & Circuit Volume
Known process load, oil volume and line size
Pump Requirements
Required flow, pressure and circulation distance
Cooling Method & Utilities
Available cooling water, voltage, phase and frequency
Controls & Safety Requirements
Communications, alarms, interlocks and plant standards
Not sure of every specification?
No problem. Send us what you know and our engineering team can help determine the correct configuration.
THC-D-18
36 kW total · 18 kW per zone
140–570 °F
THC-D-24
48 kW total · 24 kW per zone
140–570 °F
THC-D-36
72 kW total · 36 kW per zone
140–570 °F
THC-D-48
96 kW total · 48 kW per zone
140–570 °F
THC-S-18
18 kW
140–570 °F
THC-S-24
24 kW
140–570 °F
THC-S-36
36 kW
140–570 °F
THC-S-48
48 kW
140–570 °F
THC-S-60
60 kW
140–570 °F
THC-S-72
72 kW
140–570 °F
Select a section below to explore the machine
HOT OIL TCU PRODUCT SHOWCASE
THC-D-36 dual-zone controls
The THC-D-36 provides two independently controlled oil zones, with 36 kW of installed heating capacity per zone. Its cabinet-mounted color touchscreen gives operators access to temperature readings, recipe presets and fault details.
Studio imagery is based on the equipment shown in the THC-D-36 quote. The selected options and cabinet details may vary by configuration.
HOT OIL TEMPERATURE CONTROL UNIT TECHNICAL OVERVIEW
A hot oil temperature control unit is engineered for applications that require precise, stable, and high‑temperature heating beyond the limits of water‑based systems. Using thermal oil as the heat‑transfer medium allows the unit to reach temperatures typically between 300°F and 550°F (150°C–290°C) without the pressure buildup associated with steam or water. This makes hot oil TCUs ideal for molding, extrusion, laminating, and industrial processes that demand consistent thermal performance. The closed‑loop design ensures uniform heat distribution, rapid temperature recovery, and excellent energy efficiency. For manufacturers working with high‑temperature resins, composites, or tooling, a hot oil TCU provides the reliability and control needed to maintain product quality and process stability.
Hot oil TCUs offer significant advantages when operating at temperatures above the safe limits of water‑based systems. Water boils at 212°F (100°C), requiring pressurization to reach higher temperatures — which increases risk and maintenance demands. Thermal oil, however, remains stable at much higher temperatures without requiring high‑pressure operation. This allows hot oil TCUs to deliver precise, consistent heating for molds, platens, rolls, and process equipment. They also provide superior thermal stability, reduced scaling, and longer fluid life compared to water systems. For processes that require elevated temperatures, tight control, and long‑term reliability, a hot oil TCU is the preferred solution.
A hot oil TCU delivers high‑temperature performance with exceptional stability and safety. Its closed‑loop design minimizes heat loss and ensures uniform temperature distribution across tooling or process surfaces. Many units include high‑efficiency heaters, precision temperature controllers, pump‑protection systems, and safety interlocks to prevent overheating or low‑flow conditions. Thermal oil provides excellent heat‑transfer characteristics and long service life, reducing maintenance and operating costs. Hot oil TCUs are widely used in molding, extrusion, laminating, and industrial heating applications where consistent, high‑temperature control is essential. The result is improved product quality, reduced cycle times, and reliable long‑term performance.
PRODUCT DESCRIPTION
STANDARD HOT OIL TCU FEATURES
- PLC control with color HMI screen
- Job preset memory
- Heating and Cooling for maximum flexibility
- Solid, robust construction
- Durable flanged ball valves
- Safety interlocks and onboard fault indication
- Auto exhaust function
- Multi-stage adjustable heating
- Optional remote service and performance monitoring
- Sealed thermal-oil circuit to limit exposure to air
- Integrated fault alarm and signal
- Highly visible temperature reading from a distance
- Multilingual operator interface
- Visible and audible alarms
- Process synchronization where configured
- Automatic service schedule reminders
- Comprehensive I/O and fault screens
- Firmware support through MetalPress service
HOW A HOT OIL TCU WORKS
Heating, circulation and heat removal
A pump circulates thermal oil between the TCU and the process. The controller stages the heaters as needed to reach and maintain the setpoint. The cooling circuit removes heat when the process calls for it.
A dual-zone unit controls two separate oil circuits independently. Select the unit for the temperature, flow, pressure and heat load of each circuit, including restrictions through the tooling and connecting lines.
How to Specify a Hot Oil Temperature Control Unit
Engineering Fit Notes
A hot oil temperature control unit is used when a process needs stable, higher-temperature heat transfer and repeatable control across molds, platens, dies, or production equipment. Buyers comparing a hot oil TCU should consider temperature range, pump capacity, heater size, cooling method, safety controls, and how quickly the oil temperature control unit can recover after process changes. This helps connect industrial TCU selection to real production goals such as process temperature stability, part quality, cycle consistency, and reduced downtime.
MetalPress THC-D and THC-S hot oil temperature control units provide closed-loop heating and cooling for molds, dies, platens, rolls, presses, and process equipment operating above practical water-system limits. Used as an industrial temperature control unit or high-temperature mold temperature controller, each oil-based mold temperature control unit circulates thermal oil for stable heat transfer, repeatable process temperatures, and controlled recovery after load changes.
Typical applications include die casting, rubber and compression molding, composite forming, extrusion, calendering, laminating, printing, and chemical processing. A hot oil system can serve as a die casting temperature control unit when the process requires elevated die temperatures and controlled thermal cycling. Select an oil temperature control unit by maximum operating temperature, heat load, heater capacity, pump flow and pressure, circuit volume, number of zones, cooling method, controls, and safety requirements. Compare industrial temperature control units or use the mold temperature controller selection guide before specifying a system.
DUAL-ZONE OIL CIRCUIT AND STAINLESS PIPING
Independently controlled process circuits
The THC-D-36 has two independent oil circuits. Stainless-steel piping, durable flanged valves, automatic venting and staged electric heating are listed in the quoted configuration. An enclosed circuit helps limit the oil’s exposure to air.
OMRON PLC AND SERVICEABLE ELECTRICAL PANEL
Standard Omron controls with an Allen-Bradley option
The standard control package pairs an Omron PLC with an Omron color touchscreen. An Allen-Bradley PLC and HMI package is optional. Review electrical service, communication and integration needs with MetalPress when specifying the unit.
RECIPE MEMORY AND MACHINE SYNCHRONIZATION
Recall up to nine process presets
Save up to nine sets of process parameters and recall them by recipe number during changeovers. Start and stop signals can synchronize the TCU with compatible die casting machines or other process equipment. Integration is reviewed with each application.
OPERATING STATISTICS AND SERVICE REMINDERS
Track running hours by zone
The HMI shows pump running hours and filter hours for each zone. Operators can use these counters with service reminders to plan checks and maintenance around actual operating time.
I/O DIAGNOSTICS AND OPTIONAL REMOTE SUPPORT
Review component and interlock status
The PLC I/O screen shows the status of individual components and interlocks, including the emergency-stop circuit. Remote service and remote performance monitoring are separate options. Contact MetalPress Service & Parts about firmware support and available service languages.
THC-D & THC-S Models and Specifications
Compare the six single-zone and four dual-zone hot oil models in US and metric units. A dash indicates a specification to confirm with MetalPress.
Swipe to compare specifications.
| Specifications – US Standard | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Item | THC-S-18 | THC-D-18 | THC-S-24 | THC-D-24 | THC-S-36 | THC-D-36 | THC-S-48 | THC-D-48 | THC-S-60 | THC-S-72 |
| Independent zones | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 1 |
| Temperature range | 140–570 °F | 140–570 °F | 140–570 °F | 140–570 °F | 140–570 °F | 140–570 °F | 140–570 °F | 140–570 °F | 140–570 °F | 140–570 °F |
| Heating capacity per zone | 18 kW | 18 kW | 24 kW | 24 kW | 36 kW | 36 kW | 48 kW | 48 kW | 60 kW | 72 kW |
| Total heating capacity | 18 kW | 36 kW | 24 kW | 48 kW | 36 kW | 72 kW | 48 kW | 96 kW | 60 kW | 72 kW |
| Heating elements | 1 × 18 kW | 2 × 18 kW | 1 × 24 kW | 2 × 24 kW | 1 × 36 kW | 2 × 36 kW | 1 × 48 kW | 2 × 48 kW | 2 × 30 kW | 2 × 36 kW |
| Listed pump flow | 26.4 US gpm | 26.4 US gpm | 26.4 US gpm | 26.4 US gpm | 42.3 US gpm | 42.3 US gpm | 52.8 US gpm | 66 US gpm | 68.7 US gpm | 79.3 US gpm |
| Listed pump pressure | 29 psi | 29 psi | 29 psi | 29 psi | 36.3 psi | 36.3 psi | 43.5 psi | 43.5 psi | 43.5 psi | 58 psi |
| Pump motor rating | 2 hp | 2 × 2 hp | 2 hp | 2 × 2 hp | 3 hp | 2 × 4 hp | 4 hp | 2 × 5 hp | 5 hp | 7.5 hp |
| Process inlet / outlet size | ¾ in | ¾ in | 1 in | ¾ in | 1¼ in | 1 in | 1¼ in | 1½ in | 1½ in | 1½ in |
| Listed oil storage capacity | 6.6 US gal | 7.9 US gal | 6.6 US gal | 7.9 US gal | 10.6 US gal | 10.6 US gal | 10.6 US gal | 10.6 US gal | 15.9 US gal | 15.9 US gal |
| Cabinet dimensions (L × W × H) | 39.4 × 18.9 × 38.6 in | 42.5 × 26.8 × 48.4 in | 39.4 × 18.9 × 38.6 in | 42.5 × 26.8 × 48.4 in | 47.2 × 20.5 × 48 in | 49.6 × 25.6 × 51.2 in | 47.2 × 20.5 × 48 in | 49.6 × 25.6 × 51.2 in | 62.2 × 23.6 × 55.1 in | 62.2 × 23.6 × 55.1 in |
| Listed weight | 330 lb | — | 330 lb | — | 440 lb | 794 lb | — | — | 573 lb | — |
Swipe to compare specifications.
| Specifications – Metric Standard | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Item | THC-S-18 | THC-D-18 | THC-S-24 | THC-D-24 | THC-S-36 | THC-D-36 | THC-S-48 | THC-D-48 | THC-S-60 | THC-S-72 |
| Independent zones | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 1 |
| Temperature range | 60–300 °C | 60–300 °C | 60–300 °C | 60–300 °C | 60–300 °C | 60–300 °C | 60–300 °C | 60–300 °C | 60–300 °C | 60–300 °C |
| Heating capacity per zone | 18 kW | 18 kW | 24 kW | 24 kW | 36 kW | 36 kW | 48 kW | 48 kW | 60 kW | 72 kW |
| Total heating capacity | 18 kW | 36 kW | 24 kW | 48 kW | 36 kW | 72 kW | 48 kW | 96 kW | 60 kW | 72 kW |
| Heating elements | 1 × 18 kW | 2 × 18 kW | 1 × 24 kW | 2 × 24 kW | 1 × 36 kW | 2 × 36 kW | 1 × 48 kW | 2 × 48 kW | 2 × 30 kW | 2 × 36 kW |
| Listed pump flow | 100 L/min | 100 L/min | 100 L/min | 100 L/min | 160 L/min | 160 L/min | 200 L/min | 250 L/min | 260 L/min | 300 L/min |
| Listed pump pressure | 2 bar | 2 bar | 2 bar | 2 bar | 2.5 bar | 2.5 bar | 3 bar | 3 bar | 3 bar | 4 bar |
| Pump motor rating | 1.5 kW | 2 × 1.5 kW | 1.5 kW | 2 × 1.5 kW | 2.2 kW | 2 × 3 kW | 3 kW | 2 × 4 kW | 4 kW | 5.5 kW |
| Process inlet / outlet size | DN 20 | DN 20 | DN 25 | DN 20 | DN 32 | DN 25 | DN 32 | DN 40 | DN 40 | DN 40 |
| Listed oil storage capacity | 25 L | 30 L | 25 L | 30 L | 40 L | 40 L | 40 L | 40 L | 60 L | 60 L |
| Cabinet dimensions (L × W × H) | 1,000 × 480 × 980 mm | 1,080 × 680 × 1,230 mm | 1,000 × 480 × 980 mm | 1,080 × 680 × 1,230 mm | 1,200 × 520 × 1,220 mm | 1,260 × 650 × 1,300 mm | 1,200 × 520 × 1,220 mm | 1,260 × 650 × 1,300 mm | 1,580 × 600 × 1,400 mm | 1,580 × 600 × 1,400 mm |
| Listed weight | 150 kg | — | 150 kg | — | 200 kg | 360 kg | — | — | 260 kg | — |
Sizing and Configuration
Power supply. The THC-D-36 quote lists 575 V/60 Hz, 480 V/60 Hz, or 380 V/50 Hz, all three-phase. Specify site power and frequency when requesting a quote.
Controls. Omron PLC and color touchscreen are standard on the quoted configuration. Allen-Bradley controls, remote service and remote monitoring are optional.
Configuration review. Send the highest operating temperature, required flow and pressure, and plant cooling-water details. Request a confirmed connection drawing and allow clearance beyond the cabinet dimensions for manifolds, piping and service access. Ask about the operator manual and warranty for your configuration.
Hot Oil TCU ROI and Economic Evaluation
Compare forecast and current costs for circulation and heating, process scrap, and maintenance. Use a consistent production schedule and calculate each number for the same operating conditions. A shorter warm-up can add capacity. Payback uses verified or estimated costs you can avoid.
Estimated Results
- Annual net savings
- Simple payback
- Warm-up hours recovered per year
- Annual change in electricity costs
- Annual change in heat-related scrap costs
- Annual change in maintenance costs
Positive values are estimated savings. Negative values are added costs. Recovered warm-up time is a capacity estimate and is excluded from payback. The estimate uses your inputs and excludes financing, taxes and utility demand charges.
Hot Oil Temperature Control Unit Applications
Hot oil TCUs are widely used to heat injection molds, compression molds, and rubber tooling that require temperatures far above the limits of water‑based systems. Thermal oil provides stable, uniform heat distribution across the mold, improving part quality, reducing cycle variation, and preventing cold spots. This makes hot oil units ideal for engineering resins, thermosets, elastomers, and large molds that demand consistent high‑temperature performance.
Extrusion lines, calendering systems, and heated rolls rely on precise temperature control to maintain product thickness, surface finish, and material consistency. Hot oil TCUs deliver the high‑temperature stability needed to heat rolls, barrels, and dies without pressure‑related risks. Their ability to maintain tight temperature tolerances ensures smooth processing of plastics, rubber, adhesives, and composite materials.
Laminating and composite‑curing processes require uniform, high‑temperature heating to ensure proper bonding and material integrity. Hot oil TCUs provide consistent thermal energy to platens, presses, and curing fixtures, supporting applications such as panel production, engineered wood, aerospace composites, and multi‑layer laminates. The stable heat profile improves bond strength and reduces defects.
Many industrial processes require controlled heating of tanks, reactors, and vessels used for oils, adhesives, resins, waxes, and chemical mixtures. Hot oil TCUs deliver safe, high‑temperature heating without the pressure buildup associated with steam or water systems. Their closed‑loop design ensures efficient heat transfer, stable temperature control, and long‑term reliability in demanding production environments.
Hot Oil Temperature Control Unit FAQs
A hot oil temperature control unit provides safe, stable heating at temperatures far above the limits of water‑based systems. Water must be pressurized to exceed 212°F (100°C), which increases risk and maintenance demands. Thermal oil, however, remains stable at much higher temperatures without requiring high‑pressure operation. This allows hot oil TCUs to deliver precise, consistent heat to molds, platens, rolls, and process equipment. They also resist scaling, corrosion, and mineral buildup, resulting in longer system life and more reliable temperature control.
Hot oil TCUs are ideal for any process requiring high‑temperature, uniform heating. Common applications include injection molding, compression molding, rubber processing, extrusion, calendering, laminating, composite curing, and heating of tanks or vessels. These processes rely on stable thermal performance to maintain product quality, reduce cycle variation, and prevent cold spots. Hot oil systems provide the temperature range and consistency needed for demanding materials such as engineering resins, thermosets, adhesives, and composite structures.
A hot oil TCU delivers uniform, controlled heat across tooling or process surfaces, eliminating temperature fluctuations that can cause defects. The closed‑loop design ensures rapid heat recovery, tight temperature tolerances, and consistent thermal energy throughout the production cycle. This stability improves part quality, reduces scrap, and enhances repeatability. For processes involving high‑temperature resins, adhesives, or composites, precise thermal control is essential for proper curing, bonding, and material performance.
Hot oil TCUs are designed with multiple safety systems to protect operators and equipment. Common features include over‑temperature protection, low‑flow shutdown, high‑efficiency pumps with thermal safeguards, leak‑detection sensors, and automatic heater cutoffs. The closed‑loop design minimizes exposure to hot fluid, while pressure‑relief systems prevent over‑pressurization. These safety measures ensure reliable operation even in high‑temperature environments and reduce the risk of equipment damage or unplanned downtime.
Yes — hot oil temperature control units are available to customers throughout the United States, Canada, and Mexico. Manufacturers across North America rely on these systems for high‑temperature molding, extrusion, laminating, and industrial heating applications. Regional availability ensures faster delivery, reliable technical support, and access to replacement parts. Units can be configured with various heating capacities, pump sizes, and control packages to match specific process requirements.
Recent Hot Oil TCU Projects & Resources

Oil vs. Water TCUs: Which Is Right for Your Process?

THC-D-24 Hot Oil Temperature Control Unit Design & Assembly Project
Read about the process of ordering, design and assembly of a THC-D-24 hot oil control temperature unit for a plastic manufacturer in Michigan, USA

Importance of temperature control unit sizing
To increase the stability and efficiency of the die casting system, the characteristics and sizing of the temperature control unit is of vital importance.

FINALIZING & PRECOMMISSIONING THE THC‑D‑24 HOT OIL TEMPERATURE CONTROL UNIT
See finalizing and precommissioning steps for a hot-oil temperature control unit before delivery.